DMS load cell with measuring amplifier HX711AD: Unterschied zwischen den Versionen

Aus HSHL Mechatronik
Zur Navigation springen Zur Suche springen
Zeile 16: Zeile 16:
| 1 || The mass must be determined using the HX711AD load cell via Arduino and Simulink.  || 1
| 1 || The mass must be determined using the HX711AD load cell via Arduino and Simulink.  || 1
|-
|-
| 2 || The measuring range must be determined. ||  
| 2 || The measuring range must be determined. || 1
|-
|-
| 3 || The measurement uncertainty (1σ) must be determined for the measuring range and displayed as a confidence interval.||  
| 3 || The measurement uncertainty (1σ) must be determined for the measuring range and displayed as a confidence interval.|| 2
|-
|-
| 4 || The <code>on/off</code> button starts the system. The sensor must first be calibrated and display 0&thinsp;g. ||  
| 4 || The <code>on/off</code> button starts the system. The sensor must first be calibrated and display 0&thinsp;g. || 1
|-
|-
| 5 || The weight must be referenced for the measuring range. ||  
| 5 || The weight must be referenced for the measuring range. || 1
|-
|-
| 6 || The measured values ​​must be filtered/smoothed over time.  ||  
| 6 || The measured values ​​must be filtered/smoothed over time.  || 1
|-
|-
| 7 || A beep must indicate when the measured value is stable/constant. ||  
| 7 || A beep must indicate when the measured value is stable/constant. || 1
|-
|-
| 8 || The sensor system must display the weight in g on a display.  ||  
| 8 || The sensor system must display the weight in g on a display.  || 1
|-
|-
| 9 || The <code>tara</code> button resets the current weight to 0&thinsp;g (recalibration).  ||  
| 9 || The <code>tara</code> button resets the current weight to 0&thinsp;g (recalibration).  || 1
|}
|}



Version vom 16. März 2026, 13:07 Uhr

fig. 1: DMS load cell with measuring amplifier HX711AD
Autor: Onyesi John Abiagam
Sprache: DE EN

Introduction

Requirements

Table 1: Requirements for the Unit
Req. Description Priority
1 The mass must be determined using the HX711AD load cell via Arduino and Simulink. 1
2 The measuring range must be determined. 1
3 The measurement uncertainty (1σ) must be determined for the measuring range and displayed as a confidence interval. 2
4 The on/off button starts the system. The sensor must first be calibrated and display 0 g. 1
5 The weight must be referenced for the measuring range. 1
6 The measured values ​​must be filtered/smoothed over time. 1
7 A beep must indicate when the measured value is stable/constant. 1
8 The sensor system must display the weight in g on a display. 1
9 The tara button resets the current weight to 0 g (recalibration). 1

Working principle

Technical Overview

Pin Assignment

Measurement method

Measuring Circuit

Software

Arduino IDE

Simulink

Measurement

Video

Datasheets

Related Links


→ zurück zum Hauptartikel: HSHL-Mechatronik-Baukasten | Arduino Sensorsammlung