fig. 1: DMS load cell with measuring amplifier HX711AD
| Autor: |
Onyesi John Abiagam
|
| Sprache: |
DE EN
|
Introduction
Requirements
Table 1: Requirements for the Unit
| Req. |
Description |
Priority
|
| 1 |
The mass must be determined using the HX711AD load cell via Arduino and Simulink. |
1
|
| 2 |
The measuring range must be determined. |
1
|
| 3 |
The measurement uncertainty (1σ) must be determined for the measuring range and displayed as a confidence interval. |
2
|
| 4 |
The on/off button starts the system. The sensor must first be calibrated and display 0 g. |
1
|
| 5 |
The weight must be referenced for the measuring range. |
1
|
| 6 |
The measured values must be filtered/smoothed over time. |
1
|
| 7 |
A beep must indicate when the measured value is stable/constant. |
1
|
| 8 |
The sensor system must display the weight in g on a display. |
1
|
| 9 |
The tara button resets the current weight to 0 g (recalibration). |
1
|
Working principle
Technical Overview
Pin Assignment
Measurement method
Measuring Circuit
Software
Arduino IDE
Simulink
Measurement
Video
Datasheets
Related Links
→ zurück zum Hauptartikel: HSHL-Mechatronik-Baukasten | Arduino Sensorsammlung