* Now the homepage will be displayed with three main options to choose form. To setup the Topcon for following the prism choose the SETTINGS ( EINSTELL) option. A window would open showing 10 tabs for various configurations. Choose the EDM option that has a _ symbol. The EDM option will open a window that would show 6 options.  
* Now the homepage will be displayed with three main options to choose form. To setup the Topcon for following the prism choose the SETTINGS ( EINSTELL) option. A window would open showing 10 tabs for various configurations. Choose the EDM option that has a _ symbol. The EDM option will open a window that would show 6 options.  
#In the first option of Dist. Modus choose "'''Tracking'''".  
#In the first option of Dist. Modus choose "'''Tracking'''".  
#In the Reflector option choose 360 degree Prism.  
#In the Reflector option choose "'''360° Prism'''".  
#In the Prism constant input the -7 mm value.  
#In the Prism constant input the "'''-7 mm'''" value.  
#In the Blend option input the 34 mm value.  
#In the Blend option input the "'''34 mm'''" value.  
#In the illumination hold ( Illum.halten) choose the option of laser pointer.  
#In the illumination hold ( Illum.halten) choose the option of "'''Laser pointer'''".  
Upon performing this EDM setup press OK in the bottom right corner to save your selections.
Upon performing this EDM setup press OK in the bottom right corner to save your selections.



Version vom 13. Dezember 2024, 11:51 Uhr

Abb. 1: Topcon Robotic Total Spation PS-103R

Autor: Prof. Dr.-Ing. Schneider

Spezifikation

Ausrüstung

Hardware

Hardware setup guide for Topcon prism detection functionality:

  • Place the Topcon in a manner where the display of Topcon is oriented towards yourself and the laser emitter and the lens is facing the opposite direction from yourself.
  • The battery is loaded on the right side of the Topcon based on the previous orientation placement. To load the battery press the grey hatch downwards and the inner socket would open up. Place a fully charged battery in the socket by matching the symbol as shown in the image. Close the socket by returning the hatch to its original position and press the green power button just above the battery socket to turn ON the Topcon device. ( Warning: If the hatch and socket is not closed properly the Topcon may not get powered up.)
  • A Black colored stylus is inserted at the bottom right side of the screen. Please take it out and use it to operate the screen. (Warning: Do not use your finger to operate the screen as this may damage the screen).
  • When the Topcon is turned ON, the display would show a calibration mode for leveling the Topcon horizontal to the ground. In case you have placed the Topcon on the tripod please make sure the tripod is horizontally leveled with the ground. For finer adjustment of the Topcon turn the three rotating valves of the Topcon as required to exactly center the air bubble on the display. Once the Topcon is leveled press the back button. (Note: for our use case of tracking the prism on the car.
  • Now the homepage will be displayed with three main options to choose form. To setup the Topcon for following the prism choose the SETTINGS ( EINSTELL) option. A window would open showing 10 tabs for various configurations. Choose the EDM option that has a _ symbol. The EDM option will open a window that would show 6 options.
  1. In the first option of Dist. Modus choose "Tracking".
  2. In the Reflector option choose "360° Prism".
  3. In the Prism constant input the "-7 mm" value.
  4. In the Blend option input the "34 mm" value.
  5. In the illumination hold ( Illum.halten) choose the option of "Laser pointer".

Upon performing this EDM setup press OK in the bottom right corner to save your selections.

Software

Inbetriebnahme

MagnetField auf dem Feldrechner

MagnetField auf einem PC

Datenvisualisierung mit MATLAB

Abb. 2: Darstellung der Messdaten mit MATLAB

Ein Demo zur Visualisierung der Daten findet sich im Ordner Demo_ZeichneReferenzdaten (vgl. Abb. 2).

Eingangsdatum: 160722.txt
Das Datenformat zeigt Tabelle 1.

Aufruf: ZeichneReferenzdaten.m

 Header>> Delimiter(;) FileFormat(Time,Time Stamp,Horizontal Angle,Slope Distance,Vertical Angle,Azimuth,TS Type,Target Point,HR/Ant Ht.,Codes) <<
Tabelle 1: Beispiel für das Dateiformat der MagnetField Software
Time Time Stamp Horizontal Angle Slope Distance Vertical Angle Azimuth TS Type Target Point HR/Ant Ht. Codes
Zeitstempel Zeitstempel mit Datum Horizontaler Winkel in ° Schrägentfernung in m Vertikaler Winkel in ° Punkt Nr.
13:38:53 06.10.2012 13:38:53 359.5943000000 4.670 -3.3508000000 SS 106 0.000

Für Messungen in der Ebene wird die Position (x;y) vereinfacht berechnet:

x=fSchraegentfernung.*sind(fHorizontalerWinkel); % in m
y=fSchraegentfernung.*cosd(fHorizontalerWinkel); % in m

Jährliche Lizenzverlängerung

Offene Fragen

  • Auflistung der notwendigen HW und SW mit Fotos. Was braucht man? Was sind die Voraussetzungen für eine Vermessung?
  • Wer ist bei Topcon zuständig für die jährliche Lizenz-Verlängerung (Kontaktdaten)? Welche Infos müssen versendet werden (Mailvorlage)?
  • Kann die HS-Lizenz auf mehrere Jahre verlängert werden?
  • Lassen sich mit 10 Hz Zeitstempeln messen (0,1 s)? Was ist die höchste Messgeschwindigkeit? Brauchen wir dazu die RS232 Schnittstelle? Wenn ja, wie ist das Protokoll? Gibt es ein SW-Demo?
  • Lässt sich der Ablauf vereinfachen? Die Initialisierung braucht man pro Projekt nur einmal zu machen. Wie ist der verkürzte Ablauf danach?
  • Tipps für ddie Startausrichtung der Total Station: Was ist dort einzustellen?
  • Lizenz auf einem Laptop: Vereinfacht sich die Anleitung für die Bedienung?
  • Funktioniert die Vermessung auch ohne RC-5 (Prisma allein)?
  • Was bedeutet die Warnung: „Warnung: Kompensator überschritten. Korrekturbildschirm öffen“?
  • Weitere Fragen ergeben sich aus dem Dokument Anleitung Topcon Inbetriebnahme.docx.


Tipps:

  • Legen Sie bitte Unterartikel an, um die Lesbarkeit des Hauptartikels zu optimieren.
  • Heben Sie Wichtiges in Bildern hervor. Ein Beispiel finden Sie hier.
  • Fügen Sie für komplexe Einstellungen ein kurzes Video oder Animated GIF hinzu. Bilder sagen mehr als Worte.

SVN Repositorium

SVN Checkout URL: https://svn.hshl.de/svn/TopCon_Referenzsystem/trunk

Weiterführende Artikel

Inhalte im WWW